Double Selector Valve Series DS
As a part of the Mobile Accessory Family, the Parker DS Double Selector Valve diverts the A & B input ports into two separate circuits. In one position, the A & B ports are directed to C & D, and in the other position, A & B ports are directed to E & F.
This selectable circuitry permits operation of two, double-acting cylinders with:
- one four-way control valve or,
- four single-acting cylinders with two three-way control valves
• The DS is rated at 3000 PSI with SAE ports and the maximum recommend input flow is 25 GPM.
• Standard porting options are 3/4” NPT as well as SAE-12.
• The valve spool is of the open crossover type. This means that at mid stroke, ports A, D, and E are momentarily connected.
• The valve should be shifted prior to applying system pressure.
This selectable circuitry permits operation of two, double-acting cylinders with:
- one four-way control valve or,
- four single-acting cylinders with two three-way control valves
• The DS is rated at 3000 PSI with SAE ports and the maximum recommend input flow is 25 GPM.
• Standard porting options are 3/4” NPT as well as SAE-12.
• The valve spool is of the open crossover type. This means that at mid stroke, ports A, D, and E are momentarily connected.
• The valve should be shifted prior to applying system pressure.